External Claddings
LINEAR system
The LINEAR System by PROMETAL® is an exterior façade
finishing system based on strips mounted on a load-bearing structure
comprising carriers secured to existing walls.
This particular type of facing means that various compositional solutions can be achieved by exploiting the possibility of vertical, diagonal or horizontal strip installation techniques.
LINEAR is a versatile system offering an economic solution for cladding façades and canopies that also protects existing facilities against atmospheric agents.
ADVANTAGES
- Assembly is extremely simple and easy
- Versatility and adaptability to any surface
- Impressive durability: the painted surface is unaffected by humidity and dirt.
- This is an economic and high-impact system of upgrading the "look" of buildings without requiring direct intervention on existing structures
COMPOSITIONAL CHARACTERISTICS
LINEAR façade systems are based on the following elements:
1 STRIPS
2 CARRIERS
3 FLASHINGS
4 FINISHING ELEMENTS The material used in the various elements is an aluminium alloy (code 3105 H46) with the following mechanical features:
In this context, a yield fail-safe coefficient of 2.05 was obtained. Dimensions and profile verification were performed with reference to tensional status through calculation outlines involving two, three, four and more support points.
The external factors taken into consideration include wind thrust based on current legislation.
1 STRIPS
2 CARRIERS
3 FLASHINGS
4 FINISHING ELEMENTS The material used in the various elements is an aluminium alloy (code 3105 H46) with the following mechanical features:
- Tensile strength - minimum:
155 N/mm2 (15.5 Kg/ mmq) - Modulus of elasticity E:
68500 N/mm2 (6850 Kg/ mmq) - Yield load - minimum:
135 N/mm2 (13.5 Kg/ mmq)
In this context, a yield fail-safe coefficient of 2.05 was obtained. Dimensions and profile verification were performed with reference to tensional status through calculation outlines involving two, three, four and more support points.
The external factors taken into consideration include wind thrust based on current legislation.